Thursday, 2 June 2016

Steeling food?


Collotheca ambigua is a rotifer species in the family Collothecidae. The scientific name of this species is first validly published in 1883 by Hudson. Rotifers are extremely common and can be found in many freshwater environments and in moist soil, where they inhabit the thin films of water surrounding soil particles. Their habitats may include still water environments, such as lake bottoms, as well as

Monday, 30 May 2016

A safe and easy way to operate a Fluorescence microscope for beginners


LEDs are everywhere. This technology is going to roll around also the world of microscopy. For basic illumination purposes, LED technology is already established. Traditional workers will regret the death of the old fashioned Halogen light sources with their emotional high percentage of long wavelengths: think about a candle-light dinner. But LED technology is going to answer this lack of atmosphere by the offer of a large choice of color temperatures. May be this helps.

Wednesday, 18 May 2016

Extremely tiny but very useful ‘hair’



Ciliated epithelium is a type of bodily tissue that is lined with “ciliated” cells, which are basically cells that have small, hair-like protrusions known as “cilia” that can either help the cells move along the tissue or can help debris and waste move along the surface of the cells. Cilia typically move in one direction in a wavelike

Wednesday, 4 May 2016

Color fidelity and fast live image: the new Moticam 1080 Full HD Multi-Output camera is waiting for you!


Turning an ephemeral microscopic image into solid data has become the norm in working with microscopes. But the focus in daily work flow may vary. Sometimes in first instance a speedy live image with true colors for presentation purposes and discussion is needed, and the possible database may be of minor importance. In industrial QC the quantification of saved image data is the key issue. Thanks to its multi-output configuration the Moticam 1080 covers both demands. HDMI and USB signal even can be used to run the camera on HDMI and PC screen in a parallel mode.

Moticam 1080 is dedicated to the presentation and documentation of microscopic results with a clear focus on fast live image and maximum colour fidelity. The impressive 1080 (60P) HDMI live image perfectly fits to the presentation of

Monday, 2 May 2016

Euglenophyta



These organisms are unicellular and live in fresh water. Some of these organisms are photosynthetic, producing their own food, while others are heterotrophic, eating small organisms.

Euglena acus

The Euglena (genus) acus (species) is a type of Protista which lives in fresh water ponds during warm seasons. The Euglena acus produces its food through

Wednesday, 27 April 2016

Motic Images Plus 3.0 – a fresh approach for a powerful microscopy software


The marriage of light microscope and digital camera is a story of success. During the last decade, Motic’ digital products expanded into areas and markets where digital microscopy has been out of reach due to its price perception. One necessary component of this success is a powerful yet easy-to-handle software which covers concordant requirements in medical, educational and industrial applications. From the beginning, Motic Images Plus software supplied useful tools to optimize a fast live image for storage as a still image, image sequence or video. In a second step, a number of quantification tools enable multiple measurements ready to be exported for further use.

Color fidelity is a self-evident expectation on any digital camera. The new Motic Images Plus 3.0 software comes with an interactive White Balance and Background Balance in order to optimize the image background in terms of color temperature or shading. The characteristic of CMOS sensors is responded by a Color Correction tool.


A calibrated Scalebar in the live image helps for a first estimate of size and can be saved as an overlay; a variable Grid may replace the pattern of various counting chambers. But also Interactive Measurements are now possible within the Live image. The necessary calibration slide is integral part of Motic’s All-in-One camera concept and causes no additional costs.


Once the image data are saved, nearly all geometric figures can be used to outline structures to be quantified. Export of these data is possible in Excel or *txt format. An Image Comparison (recent image versus database image) is a helpful option in industrial Quality Control.

Motic Images Plus 3.0ML will start shipping as standard with the new upgraded Moticam Plus cameras (that will come out in the next coming months) as well as the new multi-function HDMI camera, the Moticam 1080.


As is normal practice with Motic, each end-user can upgrade their existing Motic Images Plus 2.0 to the new 3.0 anytime, anywhere, and free of charge. This sleek, new and thought-out software package is running with an identical interface on Windows, Apple or Linux operating systems and certainly empowers your microscope to be a more efficient scientific tool. Even more as Motic Images Plus 3.0 is a real Multilingual software; a change of language is done within a second.

Click here to download the new Motic Images Plus 3.0. 

Monday, 25 April 2016

This is not a pink cube


There is controversy on whether cobaltocalcite is a mineral on its own or if it is not. It can be described either as calcite mineral containing cobalt or as spherocobaltite containing calcium. It surely is a calcium and cobalt carbonate and, as it happens with spherocobaltite, it is pink, vitreous and it always grows incrusted on a matrix.

Wednesday, 13 April 2016

The retina, a bio-chip on the back of the eye


The structure of the eyes is in its basic form the same for all mammals. The function and operation of the eyes of mammals is thus also broadly similar.

The retina which is located on the back of the eye, is composed of very closely spaced light-sensitive cells that are in connection with the brains via the optic nerve. The light signals that reach the light-sensitive cells, are transferred to the brains via the optic nerve. The brains takes these signals and translates them into the picture what is happening before our eyes.

Friday, 8 April 2016

Quick setup guide for upright microscopes

SWITCH ON THE MICROSCOPE

Before switching on the microscope, plug-in the microscope to the power supply (1). Once this is done, switch it on (2) and gradually increase the intensity control (3).



INTERPUPILLARY DISTANCE ADJUSTMENT

Before adjusting the interpupillary distance, place the sample on the specimen holder, and select the 10X objective (4).




Tuesday, 5 April 2016

Some ideas about the FIELD of VIEW

To judge the performance of a microscope, the FIELD of VIEW (FOV) is a criterion of interest. What is this “FIELD of VIEW”? In a technical sense, we are talking about the diameter of the INTERMEDIATE IMAGE, created by the objective or, in infinity systems, by the cooperation of objective and tube lens. This intermediate image is enlarged by the eyepiece, acting as a magnifying glass. The labelling of the eyepiece shows the actual FOV in combination with its magnification, e.g. 10X/23 for a standard 10X eyepiece with FOV 23:





Finite and infinite optical system. In the Infinity Concept please note the parallel rays between objective and tube lens.

Especially in stereo microscopy, where large samples come as standard, a large FOV is appreciated for a better sample overview before going into details. But how much “more” do I see at a glance in a FOV 23, in comparison with a FOV 20? Is it worth to choose a more expensive model, or is the less expensive solution sufficient?